Chart Recorder 180mm 6 12 & 24 Point by CHINO - AH4700

The Chino AH4700 180mm hybrid chart recorder series can record continuously a maximum of 24 channels of DC voltage, thermocouples and resistance bulds (RTD) and employs a bright and clear, easy to view LCD display.

 

The LCD display provides the measured value as 1 point display with multi-points displayed simultaneously. Various measuring and recording settings can easily be done via the front panel keypad and confirmed via the LCD digital display.

Please register to access our files.

Once registered, you will be redirected to this page, and you won't have to register again to access files on this site.

We promise never to share your information with anyone! See our Privacy Policy









Overview

 

Key Features

  • Equipped with SD card (sold separately), it can record data, read and write parameter value.
  • Universal inputs with 10 DC voltage, 36 T/C & 12 RTD ranges.
  • Easy data management by communication interface with USB port and connects with PC directly. RS232C, RS422A,
    RS485 and Ethernet communication interface available as an option.
  • Data acquisition software available with application that expands from recording/management to information
    processing. Data analysis software can replay display, wave process, editing and trend display.
  • Standard alarm display/ Printing function allows up to 4 types of alarm per each input point. When alarm occurs,
    status display "ALM" flashes and measured value flashes on LCD operation screen.
  • Chart end detection function available that activates the alarm when chart end is detected.

 

Ethernet Models available

Model Type Measuring Interval Option
AH4706-E0A-NNN 6 points 1 seconds/6-points Ethernet Communication
AH4712-E0A-NNN 12 points 2 seconds/12-points Ethernet Communication
ALH724-E0A-NNN 24 points 2 seconds/24-points Ethernet Communication
       
       
       
       

 

 

 

 

 

·          

 
 
 
 
 
 

Please register to access our files.

Once registered, you will be redirected to this page, and you won't have to register again to access files on this site.

We promise never to share your information with anyone! See our Privacy Policy









Back to top

Technical Information

INPUT SPECIFICATIONS
Measuring points 6, 12, 24
  DC voltage: ±13.8mV, ±27.6mV, ±69.0mV, ±200mV, ±500mV, ±2V,±5V, ±10V, ±50V, ±50V
DC current: Max 50mA by external shunt resistor (100Ω, 250Ω) (sold separately)
Thermocouples: K, E, J, T, R, S, B, N, U, L, W-WRe26, WRe5-WRe26, PtRh40-PtRh20, NiMo-Ni, CR-AuFe, Platinel, Au/Pt
Resistance thermometers: Pt100, old Pt100, JPt100, Pt50, Pt-Co
Accuracy rating  
Measuring interval 1 second/6 points, 2 second/12 points, 2 seconds/24 points
Input resolution About 1/40,000 or better (converted to reference range)
Reference junction compensation accuracy At ambient temperature:23deg.C ±10?
K, E, J, T, N Platinel---±0.5deg. C or EMF 20μV, whichever greater
Other than above---±1.0deg. C or EMF 40μV, whichever greater
Burnout Burnout detection function for thermocouple input and RTD input. Upper burnout, lower burnout or burnout disabled is selectable for each input.
Maximum common mode voltage 30V AC/60V DC
Common mode rejection ratio 130dB or more (50/60Hz)
Normal mode rejection ratio 50dB or more (50/60Hz)
Terminal board Removable when wiring

 

DISPLAY SPECIFICATIONS

Analog display LCD bar graph 180mm
Digital display Monographic type LCD (Backlight AUTO / Always ON settable)
Dots 264 x 48 dots
Display area 184 x 22mm
Display item All channels simultaneous display, year/month/day, hour/minute, alarm activate channel, chart speed display of measuring value.
Status display REC, CARD, ALM

 

ALARM DISPLAY

Alarm display Status display "ALM" flash, measuring value flash at operation screen
Alarm types Absolute alarm, differential alarm, rate-ofchange alarm, FAIL, calendar timer, chart end
Alarm settings Individual settings, Max 4 levels/channel
Alarm output Mechanical relay 2, 6, 12 & 24 points ('a' contact)
Mechanical relay 4, 8 & 16 points ('c' contact)

 

STANDARDS (CONFORMITY PENDING)

CE marking EN61326-1
EN61010-1
*Under EMC test condition, variation in indication value is ±20% or ±2mV at maximum, whichever is larger.
UL UL61010-1 2nd edition
CSA (C-UL) CAN/CSA C22.2 No.61010-1-04
Protection IEC 60529 IP54

 

RECORDING SPECIFICATIONS

Dotting interval 5 seconds/point, 2.5 seconds/point
Interlock to chart speed
Recording method Wire-dot type 6-color ribbon
Record/Printed color  
Chart paper Fan-fold type
Total width 200mm, total length 20m, effective chart width 180mm
Chart speed 1 to 1500mm / h, in 1mm/h increments (12.5mm / h can be set exceptionally)
Periodic data printing Digital printing is added to trace printing at month / day, time, channel no., data, unit Interval (hour/time) arbitrary setting
Data printing When required, interrupt trace printing and digital print time and measuring value.
Alarm printing Alarm activated --- Time, channel no., alarm type and level
Alarm reset --- Time, channel no., alarm level Memory capacity --- Max. 48 data
List printing When required, interrupt trace printing and print date, chart speed and setting information of each channel
Message printing Print when required Up to 15 characters/message, register up to 20 characters
ON/OFF of display and recording Select ON / OFF of display per each channel, trace recording to chart, digital recording to chart, recording to SD card
Subtract printing Record difference between reference channel and measuring value or between reference value (set value) and measuring value
Zone printing 2,3 & 4 divisions
Compressed/Expanded printing Range limit is made non-linear and specific chart recording lower/upper limit is shrunk or expanded
Automatic range shift printing Recording range is shifted automatically to another set range when measured value exceeds the current range. Overlap function available
Skip function No display or printing of channels of which ranges are not set

 

GENERAL SPECIFICATIONS

Rated power voltage 100 to 240VAC, 50/60Hz
Maximum power consumption Max 40VA
100V AC balanced: 22VA
240V AC balanced: 31VA
Normal operation condition Ambient temperature range: 0 to 50ºC (20 to 65%)
Ambient humidity range: 20 to 80%RH (5 to 40ºC)
Power voltage:90 to 264V AC
Power frequency:50/60Hz ±2%
Attitude: forward tilting 0º, backward tilting 0 to 30º, left/right 0 to 10º
Case material Door --- Aluminum die-casting
Front panel --- Glass
Case --- Cold-rolled steel plate
Case color Door--- Black (equivalent of Munsell N3.0)
Glass--- Clear and colorless
Case --- Gray (equivalent of Munsell N7.0)
Mounting Panel mounting
Weight About 7.6kg
Terminal screw Power terminal, Protective conductor terminal --- M4.0
Measuring input terminal, alarm output terminal
Remote contact terminal --- M3.5
Communication terminal --- M3.0

 

OPTIONS

Remote contact By external relay contact signal (digital contact: short or open), you can select chart speed or data printing
Input points: 5, 10 & 20 points
Input signal: Digital contact signal or open collector signal
Exterior output: 5V DC/2mA
Function: 1. Record start/stop
2. Chart speed 3-speed switch
3. Data printing
4. List printing
5. Message printing
6. Operation record (Record ON/OFF condition to the designate location by bar line)
7. Integration/F value reset
8. Memory card (record start/stop)
9. Alarm output rest
10.Time correction
Alarm output Mechanical relay ('a' contact) 2, 6, 12 & 24 points
Max. load 100 to 240VAC 0.2A 30V DC 0.2A
Min. load 5V DC 10mA
Mechanical relay ('c' contact) 4, 8 & 16 points
Max. load 100 to 240VAC 0.2A 30V DC 0.2A
Min. load 5V DC 10mA
Communication interface RS232C, RS422A, RS485, Ethernet

 

 

Universal Input Types

Input type Measuring range Reference range Accuracy ratings Display resolution
DC Voltage mV -13.8 to 13.8mV ±13.8mV ±0.1%
±1digit
10μV
-27.6 to 27.6mV ±27.6mV 10μV
-69.0 to 69.0mV ±69.0mV 10μV
-200 to 200mV ±200mV 100μV
-500 to 500mV ±500mV 100μV
V -1 to 1V ± 1V 10mV
-5 to 5V ± 5V 10mV
-10 to 10V ± 10V 10mV
-20 to 20V ± 20V 10mV
-50 to 50V ± 50V 10mV
Thermocouple K -200 to 300ºC ±13.8mV ±0.1%
±1digit
0.1ºC
-200 to 600ºC ±27.6mV 0.1ºC
-200 to 1370ºC ±69.0mV 1ºC
E -200 to 200ºC ±13.8mV 0.1ºC
-200 to 350ºC ±27.6mV 0.1ºC
-200 to 900ºC ±69.0mV 1ºC
J -200 to 250ºC ±13.8mV 0.1ºC
-200 to 500ºC ±27.6mV 0.1ºC
-200 to 1200ºC ±69.0mV 1ºC
T -200 to 250ºC ±13.8mV 0.1ºC
-200 to 400ºC ±27.6mV 0.1ºC
R 0 to 1200ºC ±13.8mV 1ºC
0 to 1760ºC ±27.6mV 1ºC
S 0 to 1300ºC ±13.8mV 1ºC
0 to 1760ºC ±27.6mV 1ºC
B 0 to 1820ºC ±13.8mV 1ºC
N -200 to 400ºC ±13.8mV 0.1ºC
-200 to 750ºC ±27.6mV 0.1ºC
-200 to 1300ºC ±69.0mV 1ºC
U -200 to 250ºC ±13.8mV 0.1ºC
-200 to 500ºC ±27.6mV 0.1ºC
-200 to 600ºC ±69.0mV 0.1ºC
L -200 to 250ºC ±13.8mV 0.1ºC
-200 to 500ºC ±27.6mV 0.1ºC
-200 to 900ºC ±69.0mV 1ºC
W-WRe26 0 to 2315ºC ±69.0mV 1ºC
WRe5-WRe26 0 to 2315ºC ±69.0mV 1ºC
NiMo-Ni 0 to 290ºC ±13.8mV 0.1ºC
0 to 600ºC ±27.6mV 0.1ºC
0 to 1310ºC ±69.0mV 1ºC
Platinel II 0 to 350ºC ±13.8mV 0.1ºC
0 to 650ºC ±27.6mV 0.1ºC
0 to 1390ºC ±69.0mV 1ºC
PtRh40-PtRh20 0 to 1880ºC ±13.8mV ±0.2%
±1digit
1ºC
CR-AuFe 0 to 280 K ±6.9mV 0.1K
Au/Pt 0 to 1000ºC ±27.6mV 0.1ºC
RTD Pt100 -140 to 150ºC 160Ω ±0.1%
±1digit
0.1ºC
-200 to 300ºC 220Ω 0.1ºC
-200 to 649ºC 340Ω 0.1ºC
-200 to 850ºC 400Ω 0.1ºC
Old Pt100 -140 to 150ºC 160Ω 0.1ºC
-200 to 300ºC 220Ω 0.1ºC
-200 to 649ºC 340Ω 0.1ºC
JPt100 -140 to 150ºC 160Ω 0.1ºC
-200 to 300ºC 220Ω 0.1ºC
-200 to 649ºC 340Ω 0.1ºC
Pt50 -200 to 649ºC 220Ω 0.1ºC
Pt-Co 4 to 374K 220Ω ±0.15%
±1digit
0.1K

Please register to access our files.

Once registered, you will be redirected to this page, and you won't have to register again to access files on this site.

We promise never to share your information with anyone! See our Privacy Policy









Back to top

Installation (Click on images for larger view)

Please register to access our files.

Once registered, you will be redirected to this page, and you won't have to register again to access files on this site.

We promise never to share your information with anyone! See our Privacy Policy









Back to top

Documentation

Technical Data Sheet

Please register to access our files.

Once registered, you will be redirected to this page, and you won't have to register again to access files on this site.

We promise never to share your information with anyone! See our Privacy Policy









Back to top

Videos

Please register to access our files.

Once registered, you will be redirected to this page, and you won't have to register again to access files on this site.

We promise never to share your information with anyone! See our Privacy Policy









Back to top