Videographic Data Recorder 2 to 12 Channels by YOKOGAWA - FX1000

The FX1000 is a Paperless Data Recorder that displays real-time measured data on a colour LCD and saves data on a CompactFlash memory card.

 

Available in a 2, 4, 6, 8, 10 or 12 channel model, each able to accept thermocouple, RTD or DC voltage signals. The Yokogawa FX1000 data paperless recorder series can be connected to a network via Ethernet, which enables Email notification and web-monitoring as well as the ability to transfer files by FTP.

Please register to access our files.

Once registered, you will be redirected to this page, and you won't have to register again to access files on this site.

We promise never to share your information with anyone! See our Privacy Policy









Overview

Key Features

  • 5.7-inch, high-precision, wide viewing angle color TFT LCD
  • Many types of displays such as trend, digital, bar graph, overview, alarm, and historical trend
  • Remote viewing of the FX1000 recorder screen through the Internet
  • Multi-functional panel keys
  • Input types: DCV, TC, RTD, DI
  • Scan interval: 1s, 125ms (fast sampling)
  • Channels: 2, 4, 6, 8, 10, 12
  • Measurement accuracy: ±0.05% of reading (DCV),±0.15% of reading (TC, RTD)
  • Large (400MB) internal memory
  • CF cards up to 2GB (option)
  • USB interface (option)
  • Binary data storage
  • Network enables data redundancy
  • Space-saving design
  • Waterproof and dustproof (IP65 compliant)

 

Intuitive Display & Easy Operation

You can use the keys to switch to any of the operation screens. The operating states of memory sampling, alarms, key lock, computation, and other conditions are graphically displayed. Supports Chinese, English, German, French, and Japanese.

 

Trend dispalyTrend display Digital displayDigital display Overview displayOverview display

Displays data as waveforms. Displays each channel's scale value, industrial units, user messages, and other information.

 

In addition to displaying values digitally, it displays channel/tag, industrial units, and alarm status. Displays measurements and alarm statuse on all channels.
Trend display (log scale)Trend display (log scale) Stacked bar graphStacked bar graph  
You can display log scales for degree of vacuum (pressure input), and record the data (option). You can display and record power consumption; useful for energy saving and equipment maintenance as part of environmental programs (option).  

 

Bar graph, historical trend, and information displays (alarm summaries, message summaries, and reports) are also included.

 

 

Please register to access our files.

Once registered, you will be redirected to this page, and you won't have to register again to access files on this site.

We promise never to share your information with anyone! See our Privacy Policy









Back to top

Technical Information

General Specification

Construction

Mounting: Flush panel mounting (on a vertical plane)
Mounting may be inclined downward up to 30 degrees from a horizontal plane.
Allowable panel thickness: 2 to 26 mm
Front panel: Water- and dustproof: Complies with IEC529-IP65 (excluding side-by-side mounting)

Input

Number of inputs: FX1002: 2 channels, FX1004: 4 channels, FX1006: 6 channels,
FX1008: 8 channels, FX1010: 10 channels, FX1012: 12 channels
Measurement intervals: FX1002, DX1004: 125 ms, 250 ms
FX1006, FX1008, FX1010, FX1012: 1 s, 2 s, 5 s
Inputs: DCV (20, 60, 200 mV, 1, 2, 6, 20, 50 V, 1-5 V)
TC (R, S, B, K, E, J, T, N, W, L, U, WRe)
RTD (Pt100, JPt100)
DI (Contact input, TTL level)
DCA (with external shunt resistor attached)
Measurement/display accuracy: Standard operating conditions: Temperature: 23 ± 2°C
Humidity: 55% ± 10%RH
Power supply voltage: 90 to 132 or 180 to 250 VAC
Power supply frequency: 50/60 Hz ± 1%
Warm-up time: At least 30 minutes. Other ambient conditions such as vibration should not adversely affect the operation.

Display

Display: 5.7-inch TFT color LCD (240 × 320 dots)
* A section of the LCD monitor may contain pixels that are always on or off. The brightness of the LCD may also not be uniform due to the characteristics of the LCD. This is not a malfunction.
Display groups: Number of groups: 10
Number of channels that can be assigned to each group: Up to 6
Display color: Channel: Select from 24 colors
Background: White or black (selectable)
Trend display: Layout: Vertical, horizontal, or wide
Bar graph display: Direction: Vertical or horizontal (selectable)
Digital display: Update rate: 1 sec
Overview display: Measuring values and alarm status of all channels
Information display: Alarm summary, message summary, memory summary, report, stacked bar graph, status, Modbus status
Modbus log display: Displays the login log, error log, communication log (/C2, /C3, and /C7), FTP log (/C7), Web log (/C7), e-mail log (/C7), SNTP log (/C7), and DHCP log (/C7)
Tag display: Number of displayable characters: Up to 16
Displayable characters: English, Japanese, and Chinese
Messages: Number of displayable characters: Up to 32 alphanumeric
Displayable characters: English, Japanese, and Chinese
Historical display function: Plays back data from internal memory or external memory media.
Back light saver function: LCD back light dims or turns OFF (user selectable) if no keys have been pressed for a specified period (1, 2, 5, 10, 30, or 60 min).

Data Saving Function

External storage medium: Medium: CompactFlash memory card (CF card) (on FXs with a CF card slot)
Internal memory: Medium: Flash memory
Format: FAT32 or FAT16
Capacity: 400 MB
Maximum number of files that can be saved: 400 (total number of display data and event data files)
Operation: FIFO (First In, First Out)

Alarm Function

Number of alarm levels: Up to four for each channel
Alarm types: High limit, low limit, differential high limit, difference low limit, high rate-of-change limit, low rate-of-change limit, alarm delay high limit, and alarm delay low limit

Event Action Function

General: A particular action can be executed by particular event.
Number of event actions: 40 actions can be set

Security Functions

General: Login function or key lock function can be set for each key operation or communication operation.
Key lock function: On/off and password can be set for each operation key and FUNC operation.
Login function: User name and password to login can be set.
System administrators: 5 (with access to all operations)
Users: 30 (with access to operations based on their user access rights)

Clock

Clock: With calendar function (Western calendar)
Accuracy: ±50 ppm (0 to 50°C); does not include the delay (1 second or less) that occurs when the power is turned on.

Batch Function

General: Data display and data management with batch name, text field function and batch comment function are available.

Power Supply

Rated power supply: 100 to 240 VAC (automatic switching)
Allowable power supply voltage range: 90 to 132 or 180 to 264 VAC
Rated power supply frequency: 50/60 Hz (automatic switching)
Power consumption: Max. 45 VA (for 240 VAC power supply)

Normal Operating Conditions

Supply voltage: 90 to 132, 180 to 250 VAC
Rated power supply frequency: 50 Hz ±2%, 60 Hz ±2%
Ambient temperature: 0 to 50°C
Ambient humidity: 20 to 80% RH (at 5 to 40°C), 10 to 50% (at 40 to 50°C)

Please register to access our files.

Once registered, you will be redirected to this page, and you won't have to register again to access files on this site.

We promise never to share your information with anyone! See our Privacy Policy









Back to top

Installation (Click on images for larger view)

Please register to access our files.

Once registered, you will be redirected to this page, and you won't have to register again to access files on this site.

We promise never to share your information with anyone! See our Privacy Policy









Back to top

Documentation

Please register to access our files.

Once registered, you will be redirected to this page, and you won't have to register again to access files on this site.

We promise never to share your information with anyone! See our Privacy Policy









Back to top

Videos

Please register to access our files.

Once registered, you will be redirected to this page, and you won't have to register again to access files on this site.

We promise never to share your information with anyone! See our Privacy Policy









Back to top